Riello Sentinel Dual SDU 10000 Online UPS 10kVA / 10kW – Rack/Tower
Riello Sentinel Dual SDU 10000 — 10kVA / 10kW single-phase online double-conversion UPS, rack (6U) / tower, unity power factor, up to 95% efficiency (98% ECO), 220/230/240V, hot-swappable VRLA AGM batteries (about 3 min at full load, expandable). Swivel backlit LCD, EnergyShare outlets (2 × C13, 3 × C19), USB, RS232, REPO, communication and parallel card slots, parallel up to 3 units. Emergency function. For server rooms, edge sites, medical and industrial loads.
- Availability:
- In Stock
- Product Code:
- SDU 10000
- Brand:
- Riello UPS
![]()
![]()
![]()
![]()
-
3 JOD+ Flat Shipping Rate inside Amman
5 JOD+ Flat Shipping Rate outside Amman
-
50 JOD+ Free delivery
-
Pick Up from Store
The Riello Sentinel Dual SDU 10000 is a 10kVA / 10kW single-phase online double-conversion UPS in a versatile rack/tower format. It delivers full rated power at unity power factor (kVA = kW), with efficiency of up to 95% in online mode, hot-swappable batteries, a swivel LCD display, and programmable outlets, all in a compact 6U footprint. It is built for server rooms, edge sites, network and storage equipment, medical devices, industrial machinery, and emergency systems that cannot afford a power interruption.
ONLINE DOUBLE CONVERSION: CLEAN POWER, ZERO TRANSFER TIME
The Sentinel Dual rebuilds the output power continuously, so connected equipment always runs on filtered, stabilised, sinusoidal power with no transfer time when the mains fails. It protects against power outages, sags, surges, brownouts, frequency variation, switching transients, and harmonic distortion. The unit is classified VFI-SS-111 under IEC 62040-3, the highest performance class for UPS output.
10KVA = 10KW: UNITY POWER FACTOR
The SDU 10000 provides 10,000W of real power from its 10,000VA rating, so you can load it to its full rating. Many UPS systems at this size give up 10% or more of their rating to a lower power factor. It also handles non-linear loads such as blade servers and switch-mode power supplies.
6U RACK OR FLOOR-STANDING TOWER
The unit installs either in a 19-inch rack (two 3U modules, 6U in total, 640mm deep) or as a floor-standing tower with the two modules side by side. Plug-and-play installation and a compact footprint suit edge applications and space-limited server rooms.
WIDE INPUT TOLERANCE: 220/230/240V
Input is 220, 230, or 240V single-phase (±20% at 230V) with auto-selected 50/60Hz (±5%) and input power factor above 0.98. The output voltage is selectable (220/230/240V) with 50/60Hz output that is autosensing. The bypass accepts 180–264V.
UP TO 95% EFFICIENCY, 98% IN ECO MODE
Efficiency reaches up to 95% in online double-conversion mode and up to 98% in ECO mode, which cuts energy waste and heat. Four operating modes cover different needs:
- Online: maximum protection and output quality
- Eco: lower consumption when the mains is stable
- Smart Active: the UPS chooses the best mode based on mains quality
- Frequency Converter: output frequency can differ from input
HOT-SWAPPABLE BATTERIES
Batteries can be replaced without switching off the UPS or interrupting the load, so critical equipment stays powered during maintenance. The batteries are VRLA AGM maintenance-free, with a typical recharge time of 4–6 hours. Standard runtime is about 3 minutes at full load, and optional battery extension packs add autonomy.
ENERGYSHARE OUTLETS
Output is by terminal block plus 2 × IEC C13 and 3 × IEC C19 sockets. EnergyShare outlets prioritise critical loads and can shed non-critical equipment to extend runtime on battery.
EMERGENCY FUNCTION
An emergency function keeps emergency lighting, fire detection and extinguishing systems, and alarms running.
ROTATING BACKLIT LCD
The backlit LCD display and control panel swivels 90° to read in either rack or tower orientation. Fan speed adapts to the load in real time for low noise.
PARALLEL UP TO 3 UNITS
Connect up to 3 units to increase power, extend battery runtime, or build N+1 redundancy.
CONNECTIVITY
USB and DB9 RS232 ports with contacts, a REPO input, one slot for an optional communication card, and one slot for an optional parallel card. Fully configurable with Riello UPS software.
BUILT FOR
- Server rooms and edge computing sites
- Network and storage equipment
- Medical and laboratory systems
- Industrial machinery and control systems
- Emergency lighting, fire detection, and alarm systems
KEY SPECIFICATIONS
- Model: Riello Sentinel Dual SDU 10000
- Type: Online double-conversion, VFI-SS-111 (IEC 62040-3)
- Power: 10kVA / 10kW (unity power factor)
- Input: 220 / 230 / 240V single-phase, ±20% at 230V, 50/60Hz ±5%, PF > 0.98
- Bypass: 180–264V
- Output: 10,000VA / 10,000W, 220/230/240V selectable, 50/60Hz, sinusoidal, 3:1 crest factor
- Efficiency: up to 95% (online), up to 98% (ECO)
- Operating Modes: Online, ECO, Smart Active, Frequency Converter
- Batteries: VRLA AGM, hot-swappable, recharge 4–6h, runtime about 3 min at full load (expandable)
- Outlets: Terminal block, 2 × IEC C13, 3 × IEC C19
- Display: Swivel backlit LCD
- Interfaces: USB, DB9 RS232 + contacts, REPO input, 1 communication card slot, 1 parallel card slot
- Parallel: up to 3 units
- Format: 6U rack or tower (2 × modules)
- Dimensions: 2 × (448 × 131 × 640mm) tower / 2 × 3U × 19" × 640mm rack
- Weight: 20 + 62 kg (UPS + battery module)
- Operating Environment: 0–40°C, 5–95% RH non-condensing
- Standards: IEC EN 62040-1, IEC EN 62040-2, RoHS
- Colour: Black
- Manufacturer: Riello UPS
Related products
Marsriva KP1 EC 8000mAh Mini DC UPS for Router
JOD 29.00
Marsriva MR-UF800 - Electronic-UPS,DC UPS,Router UPS
JOD 45.00
Marsriva MR-UF600 - Electronic-UPS,DC UPS,Router UPS
JOD 35.00
Marsriva MR-UF1200 - Electronic-UPS,DC UPS,Router UPS
JOD 69.00
Marsriva MR-UF1500 - Electronic-UPS,DC UPS,Router UPS
JOD 85.00